<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-19 17-04-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 72 dBuV NOSTALGI
Pilot RDS Phase Difference
6.1 kHz 3.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
5 kHz 66 kHz 10837 0,0185
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,4 dBr 5,56 dBr 7,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Lonnie Donegan - Gamblin' man (digitally remastered) "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 66 kHz MIN: 5 kHz % above 76 kHz: 0,0185 Acquired: 2024/10/19 17.03.36 Total samples: 10837 Equivalent time: 0:09:01 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 7,0 dBr MIN: 4,4 dBr AVE: 5,56 dBr % above 12,2 dBr: 0,0 Last value: 5,1 dBr (2024/10/19 17.03.35) 16.50 16.52 16.54 16.56 16.58 17.00 17.02 0 50 100 Dev. MAX [kHz] 0 2 4 6 8 Pm [dBr]